Skip to content

EPD databases: how to find an EPD and check it has not expired

Where EPDs are published, how an EPD database differs from an LCA database, how long an EPD is valid, and what to check before you use a figure.

Published 6 min read

In short

There is no single EPD database. EPDs are published in the registries of the programme operators that verify them, in national databases, on the websites of manufacturers and trade associations, and in tools that collect them. Before you use a figure, check on the document that the EPD is within its validity period, usually five years, and note the edition of EN 15804, the declared unit and the modules covered.

Key takeaways

  • EPDs are published programme by programme and country by country. No single database holds all of them.
  • The registry of the programme operator is the place to confirm that an EPD is current.
  • An EPD database holds published declarations for products. An LCA database holds background datasets used to model them.
  • Construction EPDs usually expire five years after issue. The validity dates are printed on the document.
  • Before using a figure, check validity, edition of EN 15804, declared unit, modules, indicator and verification.

What is an EPD database?

An EPD database is a searchable collection of environmental product declarations (EPDs), or of the data they contain. The terms EPD library and EPD registry are used for the same idea. In this article, registry means the list kept by the programme operator that published an EPD, while database and library mean any collection, official or not.

There is no single EPD database that holds every declaration. EPDs are registered under many separate programmes and collected again by national bodies and software tools, so finding one usually starts with knowing where the manufacturer publishes. If you are new to the document itself, start with What is an EPD, and how do you read one?.

Where are EPDs published?

EPDs are published in four kinds of places: the registries of programme operators, national databases, the websites of manufacturers and trade associations, and aggregators or LCA tools. An EPD is verified first and then registered and published by a programme operator, so the registry is where a declaration formally lives.

WhereWhat you findKeep in mind
Registries of programme operatorsThe verified EPDs registered under that programmeEach registry covers its own programme. An EPD can be listed in more than one where programmes recognise each other
National databasesGeneric data and default values for building assessments under national rules, in some countries also product-specific dataGeneric values are meant to be conservative, and each country decides which data count
Websites of manufacturers and trade associationsThe EPD as a PDF, including sector-average EPDsThe file may not be the latest version. Compare it with the registry
Aggregators and LCA toolsEPD data from several programmes in digital formCoverage, update frequency and terms of use differ, and some charge for the data

National data sets are now part of EU law as well. Under the EU framework for the life-cycle GWP of new buildings, which has to be disclosed from 2028, Member States have to make the data needed for the calculation publicly available, including generic data and default values, and have to set those values on conservative assumptions so that generic data is not favoured over product-specific data.

One more channel is being built. As of November 2026, the Construction Products Regulation (EU) 2024/3110 provides for a digital product passport system for construction products. It is meant to carry the manufacturer's declaration of performance and conformity, which will include environmental characteristics as the regulation is phased in.

What is the difference between an EPD database and an LCA database?

An EPD database holds published results for products. An LCA database holds the background datasets that practitioners use to calculate such results. The two are often confused because both end up inside the same software.

  • EPD data describes a specific product, an average of several products, or a sector average. It comes with a declared unit, results per life-cycle module, validity dates and a verification statement.
  • LCA background data describes upstream processes such as electricity generation, transport or the supply of a raw material. It is not tied to a named product, and it is not a verified declaration.

A building assessment uses both, in an order of preference. Level(s), the EU framework for sustainable buildings, puts specific data first, such as the EPD of the product that has been specified, then average data, then generic data. For data that does not follow EN 15804, it sets a minimum bar: the last update should be no older than five years for manufacturers' data and ten years for generic data.

How long is an EPD valid?

Construction EPDs usually expire five years after issue, and the validity period is printed on the document. Practice is not uniform: Boverket, the Swedish National Board of Housing, Building and Planning, describes three to five years as usual. EN 15804 devotes a clause to the verification and validity of an EPD, and each declaration states its own dates.

Two consequences follow, as of November 2026:

  • An expired EPD is not current evidence. The product may be unchanged, but the declaration no longer stands. Ask the manufacturer for the current one.
  • Two generations are in circulation. National standards bodies had until October 2022 to withdraw the +A1 edition of EN 15804. With five-year validity, declarations prepared under +A1 can still be valid next to newer ones under +A2. Their figures are calculated differently, as EN 15804+A2 and EN 15978 explained sets out.

What should you check before using a figure?

Check nine things on the document, in this order. None of them takes long, and together they decide whether the figure can go into an assessment.

  1. Validity dates. The EPD is within its validity period on the day you use it.
  2. Registry status. The declaration is still listed by its programme operator, and you hold the latest version.
  3. Product and site. The product name and the manufacturing site match what is specified. Note whether the EPD is specific to one product, an average, or a sector EPD.
  4. Edition of the standard. EN 15804+A1 or +A2.
  5. Declared unit. Per kilogram, tonne, cubic metre, square metre at a stated thickness, or piece.
  6. Modules declared. A1–A3 only, or also A4–A5, B, C1–C4 and D. A module that is not declared is not zero.
  7. Indicator. In an +A2 EPD: GWP-total, GWP-fossil or GWP-biogenic.
  8. EPD verification. The document names an independent verifier. RICS's whole-life carbon standard asks for independent verification according to ISO 14025 and prefers third-party verification.
  9. Scenarios. The assumptions behind modules A4 to C fit your project, or you adjust them.

Record the document number, the issue date and the end of validity next to the figure. GWP of building materials by life-cycle module explains points 5 to 7 in detail.

Can you search EPDs from an AI assistant?

Yes, provided the assistant is connected to a source that holds EPD data. On its own, a general assistant answers from what it learned in training, or from whatever a web search returns, and may not be able to show the document a number came from. With a connector, it queries a catalogue and reports what the catalogue holds. Claude, ChatGPT and other assistants support the Model Context Protocol (MCP), an open standard for connecting AI applications to external systems.

Whatever the source, ask it for the same things you would look for by hand:

  • the GWP per module as printed, with the declared unit,
  • the validity dates of the EPD,
  • the document itself, so that you can check the figure,
  • a clear statement of what the source covers, because no source should be assumed to hold everything.

Quarry is one such catalogue. It is read-only, it is queried through an MCP connector or a REST API, and it returns the GWP per life-cycle module as printed in the EPD, whether the EPD is still valid, and the EPD document, citing the document for each figure. It does not hold every EPD, and it does not verify or certify declarations. Verification stays with the verifiers of the EPD programmes, and the assessment stays with you.

How to connect an assistant describes the setup. MCP servers and connectors, explained for people who design buildings covers the protocol, and AI for architects shows the kind of material questions an assistant can answer with a cited source.

Questions people ask

Sources

  1. EPDs and EN 15804 · MPA The Concrete Centre
  2. Environmental Product Declarations (EPD): an introduction, briefing paper, December 2019 · Alliance for Sustainable Building Products
  3. Mer om miljövarudeklaration för byggprodukter (EPD) · Boverket
  4. EN 15804:2012+A2:2019, official preview (contents, foreword, introduction, scope) · Slovak Office of Standards, Metrology and Testing (UNMS SR)
  5. Whole life carbon assessment for the built environment, 2nd edition · RICS
  6. Level(s) indicator 1.2: Life cycle Global Warming Potential (GWP), user manual, publication version 1.0 · European Commission, Joint Research Centre
  7. Commission Delegated Regulation (EU) 2026/52: Union framework for the national calculation of life-cycle global warming potential · European Commission, BUILD UP
  8. Regulation (EU) 2024/3110 laying down harmonised rules for the marketing of construction products · Official Journal of the European Union
  9. Construction Products Regulation: the 2024 revision · European Commission
  10. What is the Model Context Protocol (MCP)? · Model Context Protocol

More from the blog

ai for architects

AI for architects: asking about materials and getting a cited source

How AI for architects handles material questions: why a connected assistant can cite the EPD behind a carbon figure, and what you still check yourself.

7 min read

embodied carbon

Embodied carbon explained: what it is and how it is calculated

Embodied carbon is the greenhouse gas emitted to make, install, maintain and dispose of building materials. How it is defined, calculated and sourced.

6 min read

en 15804

EN 15804+A2 and EN 15978 explained for people who use EPDs

What EN 15804 requires of an EPD, what changed from +A1 to +A2, why the two are not comparable, and how EN 15978 uses EPD data in a building LCA.

7 min read