EN 15804+A2 and EN 15978 explained for people who use EPDs
What EN 15804 requires of an EPD, what changed from +A1 to +A2, why the two are not comparable, and how EN 15978 uses EPD data in a building LCA.
Published 7 min read
In short
EN 15804 is the European standard that sets the core rules for environmental product declarations (EPDs) of construction products, and its current edition is EN 15804:2012+A2:2019. EN 15978 is the building-level standard that combines product data, energy use and scenarios into an assessment of a whole building, and its 2026 edition replaced the one from 2011. Figures from +A1 and +A2 EPDs are calculated differently and should not be compared directly.
Key takeaways
- EN 15804:2012+A2:2019, with corrigendum AC:2021, is the current edition of the EPD standard for construction products as of November 2026.
- Amendment A2 split GWP into four indicators, aligned the method with the EU Environmental Footprint and made end-of-life modules and module D part of the declaration.
- A GWP from an +A1 EPD and a GWP-total from an +A2 EPD are different quantities. Record the edition next to every figure.
- EN 15978:2026 replaced EN 15978:2011 and sets out how EPD data is combined at building level.
- The EU framework for life-cycle GWP under the EPBD follows EN 15978 and uses a 50-year reference study period.
What is EN 15804?
EN 15804 is the European standard that sets the core product category rules (PCR) for environmental product declarations (EPDs) of construction products and services. Its full title is "Sustainability of construction works - Environmental product declarations - Core rules for the product category of construction products", and it is maintained by the CEN technical committee CEN/TC 350.
The standard fixes what every construction EPD has in common:
- the indicators to be declared and the way they are reported,
- the life-cycle stages covered and the processes that belong to each,
- the rules for scenarios, for the life cycle inventory and for the impact assessment, including data quality,
- the reporting of environmental and health information that life cycle assessment (LCA) does not cover,
- the conditions under which products can be compared on the basis of their EPDs.
As of November 2026 the current edition is EN 15804:2012+A2:2019, published by CEN in October 2019, with the corrigendum AC:2021. It relies on ISO 14025 for the rules of EPD programmes and on ISO 14044 for the LCA method, and it refers to ISO 21930:2017, the international core rules for construction EPDs. ISO 14025 itself was revised in June 2026. EN 15804+A2 cites the earlier edition by date, so EPDs in circulation still name it.
One thing EN 15804 leaves out on purpose: it does not say how product results are added up for a building. That is the job of EN 15978.
What changed from EN 15804+A1 to EN 15804+A2?
Amendment A2 aligned construction EPDs with the EU Environmental Footprint method and widened what has to be declared. The European Commission had mandated CEN to bring the impact assessment models, indicator units and characterisation factors of EN 15804 into line with the Product Environmental Footprint, and to use the nomenclature and data format of the International Reference Life Cycle Data System (ILCD).
| Aspect | EN 15804:2012+A1:2013 | EN 15804:2012+A2:2019 |
|---|---|---|
| Climate indicator | One GWP figure | GWP-total, GWP-fossil, GWP-biogenic and GWP-luluc |
| Impact indicators | 7 | 13 core indicators, plus 6 additional ones |
| Modules to declare | A1–A3 as the minimum | A1–A3, C1–C4 and D as a rule |
| Biogenic carbon | No separate reporting required | Reported per module in GWP-biogenic, and carbon content of product and packaging declared in kg C |
| Method | Earlier impact assessment models | Models, units and characterisation factors aligned with the EU Environmental Footprint method |
The +A2 edition superseded +A1, and national standards bodies had until October 2022 to withdraw conflicting national standards. EPDs commonly run for five years, so as of November 2026 declarations prepared under +A1 can still be within their validity period. Both generations are in circulation.
Why are +A1 and +A2 values not comparable?
Values from +A1 and +A2 EPDs are not comparable because they are not the same quantity. Three differences matter when you hold two EPDs side by side:
- The impact assessment changed. +A2 uses models, units and characterisation factors aligned with the Environmental Footprint method. The same inventory can therefore give a different indicator result under each edition.
- The headline climate figure is defined differently. +A1 has one GWP. +A2 has GWP-total, the sum of GWP-fossil, GWP-biogenic and GWP-luluc. The RICS whole-life carbon standard tells assessors to use GWP-total for +A2 data and the single GWP for +A1 data.
- The scope differs. An +A2 EPD carries end of life and module D. An +A1 EPD may stop at the factory gate, and it was not required to report biogenic carbon separately.
For practice this means three habits. Note the edition next to every figure you record. Do not rank a product with an +A1 EPD against one with an +A2 EPD on GWP alone. Where your assessment method allows data from both editions in one building model, state that you used both. GWP of building materials by life-cycle module goes through the indicators one by one.
Which modules must an EN 15804 EPD declare?
Under EN 15804+A2, an EPD declares the product stage A1–A3, the end-of-life modules C1–C4 and module D as a rule. Under +A1, only A1–A3 was required.
The standard describes types of EPD by the stages they cover:
- Cradle to gate covers A1–A3: raw material supply, transport and manufacturing. Under +A2 it comes with C1–C4 and D.
- Cradle to gate with options adds selected further modules, such as transport to site (A4) or installation (A5).
- Cradle to grave covers all stages: A1–A5, the use stage B1–B7, and C1–C4, with D alongside.
Modules A4 to C are scenario-based. They describe what the manufacturer assumed, which is why a building assessment checks them against the project.
What is EN 15978, and what changed in 2026?
EN 15978 is the building-level counterpart of EN 15804, the standard that a building LCA is calculated to. It specifies a calculation method, based on LCA and other quantified environmental information, for assessing the environmental performance of a building over its life cycle, and it sets out how the results are reported.
EN 15978:2026, with the subtitle "Requirements and guidance", replaced EN 15978:2011, whose subtitle was "Calculation method". CEN announced the new edition in April 2026. According to CEN, the standard:
- applies to new buildings, existing buildings and refurbishment projects,
- covers all stages of the building life cycle with consistent system boundaries, calculation rules and indicators,
- consolidates data from EPDs and their information modules under EN 15804:2012+A2:2019,
- adds information requirements for design for circularity.
A companion standard, EN 15941:2024, deals with data quality and the selection of data for EPDs and for building assessments.
The module structure has also been refined. The draft cited in EU law, prEN 15978:2025, subdivides several modules, for example B1 into emissions from materials and fugitive emissions of refrigerants, and D into D1 (reuse, recycling and energy recovery) and D2 (exported utilities), and it adds a module B8 for users' activities. Check the published standard for the final wording.
How does EN 15978 use EPD data at building level?
EN 15978 takes the per-module results of each EPD, multiplies them by the quantities in the building and places them in the same modules of the building model. Operational energy and water are then added, and the result is reported per module for the whole building.
- Define the building and the study period. The assessment describes the building by its functional equivalent. The EU framework for life-cycle GWP and Level(s) both use a reference study period of 50 years.
- Convert quantities to declared units. A bill of quantities in square metres has to meet an EPD declared per tonne or per cubic metre.
- Take A1–A3 from the EPD. Product-stage data is the least dependent on the project.
- Check the scenario modules. RICS gives an example: if an EPD assumes 50 km of road transport for A4 and the site is 75 km away, the A4 figure is scaled to 150%. Where a scenario cannot be adjusted, generic data is used instead.
- Count replacements. How often a product is replaced within the study period (module B4) depends on its service life.
- Keep module D apart. It is reported next to the life-cycle total.
Data is chosen by a hierarchy. Level(s) puts specific data, such as the EPD of the product actually specified, ahead of average data and generic data.
How do EN 15804 and EN 15978 relate to EU law?
Both standards are the technical basis of the EU rules on the carbon footprint of buildings and products, as of November 2026.
- EPBD. Delegated Regulation (EU) 2026/52, published on 4 May 2026, requires the life-cycle GWP of new buildings to be calculated following the relevant parts of EN 15978. It names the 2011 edition and any subsequent standard. Results are expressed in kg CO₂ eq per m² of useful floor area. Data declared under the Construction Products Regulation is used when available, and product-specific data calculated to EN 15804 may be used where national law permits. Details are in EPBD and whole-life carbon.
- Construction Products Regulation (EU) 2024/3110. Annex II lists 19 predetermined environmental characteristics that harmonised technical specifications for construction products have to cover. The list begins with the four climate change indicators, which are the same split that EN 15804+A2 introduced.
An assistant connected to Quarry returns the GWP per module as printed in the EPD, its validity dates and the document. The edition of EN 15804 is stated in the document itself, and that is where to confirm it before figures from different EPDs go into one model.
Questions people ask
Sources
- EN 15804:2012+A2:2019, official preview (contents, foreword, introduction, scope) · Slovak Office of Standards, Metrology and Testing (UNMS SR)
- EVS-EN 15804:2012+A2:2019 and corrigendum AC:2021 · Estonian Centre for Standardisation and Accreditation (EVS)
- DIN EN 15804:2022-03, German version of EN 15804:2012+A2:2019 + AC:2021 · DIN
- ISO 14025:2026 Environmental statements and programmes for products: Environmental product declarations (EPDs) · Standards Norway
- EF method and EN 15804 · European Commission, European Platform on Life Cycle Assessment
- Whole life carbon assessment for the built environment, 2nd edition · RICS
- Environmental Product Declarations (EPD): an introduction, briefing paper, December 2019 · Alliance for Sustainable Building Products
- Level(s) indicator 1.2: Life cycle Global Warming Potential (GWP), user manual, publication version 1.0 · European Commission, Joint Research Centre
- EN 15978:2026 - A Harmonized Method to Assess the Environmental Performance of Buildings · CEN-CENELEC
- EVS-EN 15978:2026 Sustainability of construction works - Assessment of environmental performance of buildings - Requirements and guidance · Estonian Centre for Standardisation and Accreditation (EVS)
- EVS-EN 15941:2024 Data quality for environmental assessment of products and construction work - Selection and use of data · Estonian Centre for Standardisation and Accreditation (EVS)
- Commission Delegated Regulation (EU) 2026/52: Union framework for the national calculation of life-cycle global warming potential · European Commission, BUILD UP
- Regulation (EU) 2024/3110 laying down harmonised rules for the marketing of construction products · Official Journal of the European Union