[{"data":1,"prerenderedAt":384},["ShallowReactive",2],{"blog-post-\u002Fblog\u002Fwhat-is-an-epd":3,"blog-related-\u002Fblog\u002Fwhat-is-an-epd":368},{"id":4,"title":5,"author":6,"body":7,"description":276,"extension":277,"faq":278,"keywords":295,"meta":302,"navigation":303,"path":304,"primaryKeyword":296,"publishedAt":305,"rawbody":306,"readingMinutes":307,"seo":308,"sitemap":309,"sources":310,"stem":358,"summary":359,"takeaways":360,"updatedAt":305,"words":366,"__hash__":367},"blog\u002Fblog\u002Fwhat-is-an-epd.md","What is an EPD, and how do you read one?","Quarry",{"type":8,"value":9,"toc":266},"minimark",[10,15,19,22,45,48,52,55,122,125,129,132,182,186,189,192,195,199,202,205,225,232,236,239,263],[11,12,14],"h2",{"id":13},"what-is-an-epd","What is an EPD?",[16,17,18],"p",{},"An EPD (environmental product declaration) is a document in which a manufacturer declares the environmental impacts of a product over its life cycle. The figures are calculated by life cycle assessment (LCA) under published rules and checked by an independent verifier. In construction, people who ask \"what is an EPD\" usually need one thing from it: the global warming potential (GWP) of a product, stated per unit and per life-cycle stage.",[16,20,21],{},"Three layers of rules stand behind a construction EPD:",[23,24,25,33,39],"ul",{},[26,27,28,32],"li",{},[29,30,31],"strong",{},"ISO 14025"," sets the principles and requirements for EPD programmes and the declarations they publish, and builds on the LCA standards ISO 14040 and ISO 14044. Its second edition, ISO 14025:2026, was published in June 2026 and replaced ISO 14025:2006. The 2006 edition called these documents \"Type III environmental declarations\", a term still printed on EPDs issued under it.",[26,34,35,38],{},[29,36,37],{},"EN 15804"," provides the core product category rules (PCR) for construction products and services in Europe. It fixes which indicators are declared, which life-cycle stages are covered and how the LCA is calculated. As of November 2026 the current edition is EN 15804:2012+A2:2019, with a corrigendum from 2021. ISO 21930:2017 sets core rules for construction EPDs at international level.",[26,40,41,44],{},[29,42,43],{},"Complementary PCR"," for a product group, such as cement or timber, add detail on top of EN 15804.",[16,46,47],{},"An EPD reports results. It does not rate the product, and it sets no threshold that a product has to pass.",[11,49,51],{"id":50},"what-does-an-epd-contain","What does an EPD contain?",[16,53,54],{},"An EN 15804 EPD contains general information about the product and the declaration, a table of environmental indicators for each life-cycle module, the scenarios behind those figures and, where relevant, additional environmental and health information. Layout differs between programmes. The content is set by clause 7 of the standard.",[56,57,58,74],"table",{},[59,60,61],"thead",{},[62,63,64,68,71],"tr",{},[65,66,67],"th",{},"Part of the EPD",[65,69,70],{},"What you find there",[65,72,73],{},"Why it matters",[75,76,77,89,100,111],"tbody",{},[62,78,79,83,86],{},[80,81,82],"td",{},"General information",[80,84,85],{},"Manufacturer, product description, declared unit, programme operator, the PCR used, issue and expiry dates, verification statement",[80,87,88],{},"Tells you what was declared, by whom and until when",[62,90,91,94,97],{},[80,92,93],{},"Results per module",[80,95,96],{},"Environmental impact indicators such as GWP, resource use, waste and output flows, biogenic carbon content",[80,98,99],{},"These are the figures that go into a building assessment",[62,101,102,105,108],{},[80,103,104],{},"Scenarios and technical information",[80,106,107],{},"Assumptions for transport, installation, use and end of life",[80,109,110],{},"Shows whether the modelled scenario fits your project",[62,112,113,116,119],{},[80,114,115],{},"Additional information",[80,117,118],{},"Release of dangerous substances to indoor air, soil and water during use, where relevant",[80,120,121],{},"Covers aspects that LCA does not",[16,123,124],{},"In an EPD that follows EN 15804+A2, the climate result is split into four indicators: GWP-fossil, GWP-biogenic, GWP-luluc (land use and land use change) and GWP-total, which is the sum of the other three.",[11,126,128],{"id":127},"how-do-you-read-an-epd","How do you read an EPD?",[16,130,131],{},"Read the frame before the figures: the declared unit, the edition of the standard and the modules covered, and only then the indicator you need. A GWP value lifted without that frame is easy to misuse.",[133,134,135,141,153,164,170,176],"ol",{},[26,136,137,140],{},[29,138,139],{},"Declared unit."," Every figure applies to one declared unit, for example 1 m³, 1 tonne or 1 m² at a stated thickness. Convert it to the quantity in your project before you compare anything.",[26,142,143,146,147,152],{},[29,144,145],{},"Edition of the standard."," The EPD states whether it follows EN 15804+A1 or +A2. The two calculate impacts differently, as described in ",[148,149,151],"a",{"href":150},"\u002Fblog\u002Fen-15804-en-15978-explained","EN 15804+A2 and EN 15978 explained",".",[26,154,155,158,159,163],{},[29,156,157],{},"Modules covered."," Results are given per module: A1–A3 for the product stage, A4–A5 for construction, B for use, C1–C4 for end of life and D for benefits and loads beyond the system boundary. Not every EPD declares every module. ",[148,160,162],{"href":161},"\u002Fblog\u002Fgwp-building-materials-a1-a3","GWP of building materials by life-cycle module"," explains each one.",[26,165,166,169],{},[29,167,168],{},"Indicator."," In an +A2 EPD, decide whether you need GWP-total or one of its parts, and record which one you used.",[26,171,172,175],{},[29,173,174],{},"Scenarios."," Figures for transport, installation and end of life rest on the manufacturer's scenario. Check that it resembles your project before you rely on them.",[26,177,178,181],{},[29,179,180],{},"Specific or average."," An EPD can describe one product from one plant, an average across several plants or products, or a sector average published by a trade association.",[11,183,185],{"id":184},"who-verifies-an-epd-and-is-there-such-a-thing-as-an-epd-certificate","Who verifies an EPD, and is there such a thing as an EPD certificate?",[16,187,188],{},"An EPD is checked by an independent verifier and then registered and published by a programme operator. The verifier is an LCA expert who took no part in preparing the declaration, and who checks it against EN 15804, the PCR and the instructions of the programme. RICS's whole-life carbon standard asks for EPDs that are independently verified according to ISO 14025 and prefers third-party verification.",[16,190,191],{},"EPD verification is not product certification. People search for \"EPD certificate\" and \"EPD certification\", but what exists is a verified, registered declaration. Verification confirms that the declaration was prepared according to the rules, not that the product has a low impact.",[16,193,194],{},"The same point separates an EPD from an ecolabel. The ISO 14020 family of standards distinguishes ecolabels, self-declared environmental claims and EPDs. An EPD publishes the figures and leaves the judgement to the reader.",[11,196,198],{"id":197},"how-do-i-check-that-an-epd-is-still-valid","How do I check that an EPD is still valid?",[16,200,201],{},"Look at the validity dates in the general information at the front of the EPD, and confirm that the declaration is still listed in the register of the programme operator that published it. Construction EPDs usually expire five years after issue. Boverket, the Swedish National Board of Housing, Building and Planning, describes three to five years as usual, so read the date instead of assuming it.",[16,203,204],{},"Three further checks take a minute:",[23,206,207,213,219],{},[26,208,209,212],{},[29,210,211],{},"Version."," Make sure you hold the latest registered version, not an older PDF saved in a project folder.",[26,214,215,218],{},[29,216,217],{},"Edition."," National standards bodies had until October 2022 to withdraw the +A1 edition of EN 15804, and EPDs commonly run for five years. As of November 2026, declarations prepared under +A1 can therefore still be within their validity period.",[26,220,221,224],{},[29,222,223],{},"Match."," Check that the product name and the manufacturing site in the EPD are the ones you are specifying.",[16,226,227,228,152],{},"If your assistant is connected to a product catalogue such as Quarry, it can return the validity dates and the EPD document together with the GWP per module as printed, which shortens the lookup. Reading the declaration remains your job. Where EPDs are published, and what else to check, is covered in ",[148,229,231],{"href":230},"\u002Fblog\u002Fepd-database-find-valid-epd","EPD databases: how to find an EPD and check it has not expired",[11,233,235],{"id":234},"is-an-epd-mandatory","Is an EPD mandatory?",[16,237,238],{},"An EPD is not mandatory as a rule: under ISO 14025 and EN 15804 it is a declaration that a manufacturer chooses to publish. As of November 2026, however, EU law is making the data in it compulsory step by step, and national rules can go further.",[23,240,241,247,257],{},[26,242,243,246],{},[29,244,245],{},"Construction Products Regulation (EU) 2024\u002F3110."," Where a product is covered by a harmonised technical specification adopted under the new regulation, the manufacturer's declaration of performance and conformity has to include the product's environmental performance over its life cycle. The four climate change indicators come first, from 8 January 2026. Further indicators follow from 9 January 2030 and 9 January 2032. The obligation therefore arrives product family by product family, as specifications are adopted.",[26,248,249,252,253,152],{},[29,250,251],{},"Energy Performance of Buildings Directive."," The life-cycle GWP of new buildings has to be calculated and disclosed in the energy performance certificate from January 2028 for buildings above 1,000 m² and from January 2030 for all new buildings. The EU calculation framework gives priority to product data declared under the Construction Products Regulation and lets Member States permit product-specific data calculated to EN 15804. See ",[148,254,256],{"href":255},"\u002Fblog\u002Fepbd-whole-life-carbon-gwp","EPBD and whole-life carbon",[26,258,259,262],{},[29,260,261],{},"Clients and schemes."," Green building certification and lower-carbon public procurement increasingly ask for EPDs.",[16,264,265],{},"So the EPD itself remains voluntary, while declaring life-cycle climate data for construction products is becoming a legal duty.",{"title":267,"searchDepth":268,"depth":268,"links":269},"",2,[270,271,272,273,274,275],{"id":13,"depth":268,"text":14},{"id":50,"depth":268,"text":51},{"id":127,"depth":268,"text":128},{"id":184,"depth":268,"text":185},{"id":197,"depth":268,"text":198},{"id":234,"depth":268,"text":235},"What an EPD is, what it contains, who verifies it, whether it is mandatory, and how to check that it is still valid before you use a figure from it.","md",[279,282,284,287,289,292],{"question":280,"answer":281},"What is an EPD in construction?","In construction, an EPD is a manufacturer's verified declaration of the environmental impacts of a product, calculated by life cycle assessment under EN 15804 and ISO 14025. It reports indicators such as global warming potential per declared unit and per life-cycle module, from raw material supply to end of life. Designers and LCA consultants use it as product data in whole-building carbon assessments.",{"question":51,"answer":283},"An EPD contains general information (manufacturer, product, declared unit, programme operator, validity dates and verification statement), a results table with environmental indicators for each declared life-cycle module, the scenarios assumed for transport, installation, use and end of life, and where relevant additional information on substances released during use. EN 15804 fixes this content for construction products.",{"question":285,"answer":286},"How do I check whether an EPD is still valid?","Find the issue date and the end of validity in the general information at the front of the EPD, then confirm that the declaration is still listed in the register of the programme operator that published it. Most construction EPDs run for five years. Check as well that you hold the latest version and that the product and manufacturing site match what you are specifying.",{"question":235,"answer":288},"Publishing an EPD is voluntary. As of November 2026, however, the EU Construction Products Regulation (EU) 2024\u002F3110 phases in mandatory declaration of life-cycle climate indicators for products covered by new harmonised specifications, and the Energy Performance of Buildings Directive requires life-cycle GWP to be disclosed for large new buildings from 2028 and for all new buildings from 2030.",{"question":290,"answer":291},"Who verifies an EPD?","An independent verifier with LCA expertise, who took no part in preparing the declaration, checks the underlying study and the document against EN 15804, the product category rules and the instructions of the programme. The programme operator then registers and publishes the EPD. The document names the verifier and states how the verification was carried out.",{"question":293,"answer":294},"Is an EPD the same as an EPD certificate or an ecolabel?","No. An EPD is a declaration of calculated environmental impacts, not a certificate that a product reaches a performance level. Verification confirms that the declaration was prepared according to the rules. The ISO 14020 family of standards treats ecolabels, self-declared claims and EPDs as separate things. An EPD publishes the figures and leaves comparison and judgement to the user.",[296,297,298,299,300,301],"what is an epd","environmental product declaration","epd certificate","epd certification","iso 14025","epd verification",{},true,"\u002Fblog\u002Fwhat-is-an-epd","2026-11-17","## What is an EPD?\n\nAn EPD (environmental product declaration) is a document in which a manufacturer declares the environmental impacts of a product over its life cycle. The figures are calculated by life cycle assessment (LCA) under published rules and checked by an independent verifier. In construction, people who ask \"what is an EPD\" usually need one thing from it: the global warming potential (GWP) of a product, stated per unit and per life-cycle stage.\n\nThree layers of rules stand behind a construction EPD:\n\n- **ISO 14025** sets the principles and requirements for EPD programmes and the declarations they publish, and builds on the LCA standards ISO 14040 and ISO 14044. Its second edition, ISO 14025:2026, was published in June 2026 and replaced ISO 14025:2006. The 2006 edition called these documents \"Type III environmental declarations\", a term still printed on EPDs issued under it.\n- **EN 15804** provides the core product category rules (PCR) for construction products and services in Europe. It fixes which indicators are declared, which life-cycle stages are covered and how the LCA is calculated. As of November 2026 the current edition is EN 15804:2012+A2:2019, with a corrigendum from 2021. ISO 21930:2017 sets core rules for construction EPDs at international level.\n- **Complementary PCR** for a product group, such as cement or timber, add detail on top of EN 15804.\n\nAn EPD reports results. It does not rate the product, and it sets no threshold that a product has to pass.\n\n## What does an EPD contain?\n\nAn EN 15804 EPD contains general information about the product and the declaration, a table of environmental indicators for each life-cycle module, the scenarios behind those figures and, where relevant, additional environmental and health information. Layout differs between programmes. The content is set by clause 7 of the standard.\n\n| Part of the EPD                     | What you find there                                                                                                                | Why it matters                                           |\n| ----------------------------------- | ---------------------------------------------------------------------------------------------------------------------------------- | -------------------------------------------------------- |\n| General information                 | Manufacturer, product description, declared unit, programme operator, the PCR used, issue and expiry dates, verification statement | Tells you what was declared, by whom and until when      |\n| Results per module                  | Environmental impact indicators such as GWP, resource use, waste and output flows, biogenic carbon content                         | These are the figures that go into a building assessment |\n| Scenarios and technical information | Assumptions for transport, installation, use and end of life                                                                       | Shows whether the modelled scenario fits your project    |\n| Additional information              | Release of dangerous substances to indoor air, soil and water during use, where relevant                                           | Covers aspects that LCA does not                         |\n\nIn an EPD that follows EN 15804+A2, the climate result is split into four indicators: GWP-fossil, GWP-biogenic, GWP-luluc (land use and land use change) and GWP-total, which is the sum of the other three.\n\n## How do you read an EPD?\n\nRead the frame before the figures: the declared unit, the edition of the standard and the modules covered, and only then the indicator you need. A GWP value lifted without that frame is easy to misuse.\n\n1. **Declared unit.** Every figure applies to one declared unit, for example 1 m³, 1 tonne or 1 m² at a stated thickness. Convert it to the quantity in your project before you compare anything.\n2. **Edition of the standard.** The EPD states whether it follows EN 15804+A1 or +A2. The two calculate impacts differently, as described in [EN 15804+A2 and EN 15978 explained](\u002Fblog\u002Fen-15804-en-15978-explained).\n3. **Modules covered.** Results are given per module: A1–A3 for the product stage, A4–A5 for construction, B for use, C1–C4 for end of life and D for benefits and loads beyond the system boundary. Not every EPD declares every module. [GWP of building materials by life-cycle module](\u002Fblog\u002Fgwp-building-materials-a1-a3) explains each one.\n4. **Indicator.** In an +A2 EPD, decide whether you need GWP-total or one of its parts, and record which one you used.\n5. **Scenarios.** Figures for transport, installation and end of life rest on the manufacturer's scenario. Check that it resembles your project before you rely on them.\n6. **Specific or average.** An EPD can describe one product from one plant, an average across several plants or products, or a sector average published by a trade association.\n\n## Who verifies an EPD, and is there such a thing as an EPD certificate?\n\nAn EPD is checked by an independent verifier and then registered and published by a programme operator. The verifier is an LCA expert who took no part in preparing the declaration, and who checks it against EN 15804, the PCR and the instructions of the programme. RICS's whole-life carbon standard asks for EPDs that are independently verified according to ISO 14025 and prefers third-party verification.\n\nEPD verification is not product certification. People search for \"EPD certificate\" and \"EPD certification\", but what exists is a verified, registered declaration. Verification confirms that the declaration was prepared according to the rules, not that the product has a low impact.\n\nThe same point separates an EPD from an ecolabel. The ISO 14020 family of standards distinguishes ecolabels, self-declared environmental claims and EPDs. An EPD publishes the figures and leaves the judgement to the reader.\n\n## How do I check that an EPD is still valid?\n\nLook at the validity dates in the general information at the front of the EPD, and confirm that the declaration is still listed in the register of the programme operator that published it. Construction EPDs usually expire five years after issue. Boverket, the Swedish National Board of Housing, Building and Planning, describes three to five years as usual, so read the date instead of assuming it.\n\nThree further checks take a minute:\n\n- **Version.** Make sure you hold the latest registered version, not an older PDF saved in a project folder.\n- **Edition.** National standards bodies had until October 2022 to withdraw the +A1 edition of EN 15804, and EPDs commonly run for five years. As of November 2026, declarations prepared under +A1 can therefore still be within their validity period.\n- **Match.** Check that the product name and the manufacturing site in the EPD are the ones you are specifying.\n\nIf your assistant is connected to a product catalogue such as Quarry, it can return the validity dates and the EPD document together with the GWP per module as printed, which shortens the lookup. Reading the declaration remains your job. Where EPDs are published, and what else to check, is covered in [EPD databases: how to find an EPD and check it has not expired](\u002Fblog\u002Fepd-database-find-valid-epd).\n\n## Is an EPD mandatory?\n\nAn EPD is not mandatory as a rule: under ISO 14025 and EN 15804 it is a declaration that a manufacturer chooses to publish. As of November 2026, however, EU law is making the data in it compulsory step by step, and national rules can go further.\n\n- **Construction Products Regulation (EU) 2024\u002F3110.** Where a product is covered by a harmonised technical specification adopted under the new regulation, the manufacturer's declaration of performance and conformity has to include the product's environmental performance over its life cycle. The four climate change indicators come first, from 8 January 2026. Further indicators follow from 9 January 2030 and 9 January 2032. The obligation therefore arrives product family by product family, as specifications are adopted.\n- **Energy Performance of Buildings Directive.** The life-cycle GWP of new buildings has to be calculated and disclosed in the energy performance certificate from January 2028 for buildings above 1,000 m² and from January 2030 for all new buildings. The EU calculation framework gives priority to product data declared under the Construction Products Regulation and lets Member States permit product-specific data calculated to EN 15804. See [EPBD and whole-life carbon](\u002Fblog\u002Fepbd-whole-life-carbon-gwp).\n- **Clients and schemes.** Green building certification and lower-carbon public procurement increasingly ask for EPDs.\n\nSo the EPD itself remains voluntary, while declaring life-cycle climate data for construction products is becoming a legal duty.",6,{"title":5,"description":276},{"loc":304,"lastmod":305},[311,315,319,323,326,330,334,338,342,346,350,354],{"title":312,"publisher":313,"url":314},"EN 15804:2012+A2:2019, official preview (contents, foreword, introduction, scope)","Slovak Office of Standards, Metrology and Testing (UNMS SR)","https:\u002F\u002Fnormy.normoff.gov.sk\u002Fnorma\u002F130702\u002Fnahlad",{"title":316,"publisher":317,"url":318},"DIN EN 15804:2022-03, German version of EN 15804:2012+A2:2019 + AC:2021","DIN","https:\u002F\u002Fwww.din.de\u002Fen\u002Fwdc-beuth:din21:344735627",{"title":320,"publisher":321,"url":322},"ISO 14025:2026 Environmental statements and programmes for products: Environmental product declarations (EPDs)","Standards Norway","https:\u002F\u002Fonline.standard.no\u002Fen\u002Fiso-14025-2026",{"title":324,"publisher":317,"url":325},"ISO 14025, edition 2026-06","https:\u002F\u002Fwww.din.de\u002Fen\u002Fwdc-beuth:din21:404031184",{"title":327,"publisher":328,"url":329},"SS-EN ISO 14025:2026","Swedish Institute for Standards (SIS)","https:\u002F\u002Fwww.sis.se\u002Fen\u002Fprodukter\u002Fmanagement-system\u002Fenvironmental-management-systems-environmental-management\u002Fss-en-iso-140252026\u002F",{"title":331,"publisher":332,"url":333},"Mer om miljövarudeklaration för byggprodukter (EPD)","Boverket","https:\u002F\u002Fwww.boverket.se\u002Fsv\u002Fbyggande\u002Fhallbart-byggande-och-forvaltning\u002Flivscykelanalys\u002Fmiljodata-och-lca-verktyg\u002Fmiljovarudeklaration-for-byggprodukter-epd\u002F",{"title":335,"publisher":336,"url":337},"EPDs and EN 15804","MPA The Concrete Centre","https:\u002F\u002Fconcretecentre.com\u002FCodes\u002FEnvironmental-Assessment\u002FEPD.aspx",{"title":339,"publisher":340,"url":341},"Environmental Product Declarations (EPD): an introduction, briefing paper, December 2019","Alliance for Sustainable Building Products","https:\u002F\u002Fasbp.org.uk\u002Fwp-content\u002Fuploads\u002F2019\u002F12\u002FASBP-Briefing-paper-EPD-Part-1.-An-Introduction.pdf",{"title":343,"publisher":344,"url":345},"Whole life carbon assessment for the built environment, 2nd edition","RICS","https:\u002F\u002Fwww.rics.org\u002Fcontent\u002Fdam\u002Fricsglobal\u002Fdocuments\u002Fstandards\u002FWhole_life_carbon_assessment_PS_Sept23.pdf",{"title":347,"publisher":348,"url":349},"Regulation (EU) 2024\u002F3110 laying down harmonised rules for the marketing of construction products","Official Journal of the European Union","https:\u002F\u002Feur-lex.europa.eu\u002Feli\u002Freg\u002F2024\u002F3110\u002Foj",{"title":351,"publisher":352,"url":353},"Energy Performance of Buildings Directive","European Commission","https:\u002F\u002Fenergy.ec.europa.eu\u002Ftopics\u002Fenergy-efficiency\u002Fenergy-performance-buildings\u002Fenergy-performance-buildings-directive_en",{"title":355,"publisher":356,"url":357},"Commission Delegated Regulation (EU) 2026\u002F52: Union framework for the national calculation of life-cycle global warming potential","European Commission, BUILD UP","https:\u002F\u002Fbuild-up.ec.europa.eu\u002Fen\u002Fresources-and-tools\u002Fpublications\u002Funion-framework-national-calculation-life-cycle-global-warming","blog\u002Fwhat-is-an-epd","An EPD (environmental product declaration) is a verified document in which a manufacturer reports the environmental impacts of a product over its life cycle, calculated by life cycle assessment under fixed rules. For construction products in Europe those rules are EN 15804 and ISO 14025. To read one, start with the declared unit, the validity dates and the modules covered, then take the figure you need from the results table.",[361,362,363,364,365],"An EPD reports calculated impacts per declared unit and per life-cycle module. It does not rate the product or certify that it is low-carbon.","Construction EPDs in Europe follow EN 15804:2012+A2:2019 and ISO 14025. ISO 14025:2026 replaced the 2006 edition in June 2026.","An EPD is independently verified and carries a validity period, usually five years. The dates are printed on the document.","Publishing an EPD is voluntary, but Regulation (EU) 2024\u002F3110 phases in mandatory declaration of life-cycle climate indicators for construction products.","Read the declared unit, the edition of the standard and the modules covered before you read any GWP figure.",1292,"h4fsWkqAlPFQ6LMa9Vh30DfrXfgd5GLprlonARdcLQ8",[369,375,380],{"path":370,"title":371,"description":372,"publishedAt":305,"updatedAt":305,"primaryKeyword":373,"readingMinutes":374},"\u002Fblog\u002Fai-for-architects-material-data","AI for architects: asking about materials and getting a cited source","How AI for architects handles material questions: why a connected assistant can cite the EPD behind a carbon figure, and what you still check yourself.","ai for architects",7,{"path":376,"title":377,"description":378,"publishedAt":305,"updatedAt":305,"primaryKeyword":379,"readingMinutes":307},"\u002Fblog\u002Fembodied-carbon-explained","Embodied carbon explained: what it is and how it is calculated","Embodied carbon is the greenhouse gas emitted to make, install, maintain and dispose of building materials. How it is defined, calculated and sourced.","embodied carbon",{"path":150,"title":381,"description":382,"publishedAt":305,"updatedAt":305,"primaryKeyword":383,"readingMinutes":374},"EN 15804+A2 and EN 15978 explained for people who use EPDs","What EN 15804 requires of an EPD, what changed from +A1 to +A2, why the two are not comparable, and how EN 15978 uses EPD data in a building LCA.","en 15804",1795523510607]