[{"data":1,"prerenderedAt":367},["ShallowReactive",2],{"blog-post-\u002Fblog\u002Fsustainable-building-materials-epd-data":3,"blog-related-\u002Fblog\u002Fsustainable-building-materials-epd-data":353},{"id":4,"title":5,"author":6,"body":7,"description":270,"extension":271,"faq":272,"keywords":288,"meta":296,"navigation":297,"path":298,"primaryKeyword":289,"publishedAt":299,"rawbody":300,"readingMinutes":301,"seo":302,"sitemap":303,"sources":304,"stem":343,"summary":344,"takeaways":345,"updatedAt":299,"words":351,"__hash__":352},"blog\u002Fblog\u002Fsustainable-building-materials-epd-data.md","Sustainable building materials: how to compare them with EPD data","Quarry",{"type":8,"value":9,"toc":261},"minimark",[10,15,19,22,25,28,37,41,44,47,125,128,135,146,157,160,164,167,170,173,183,187,190,210,218,222,225,251,254],[11,12,14],"h2",{"id":13},"what-makes-sustainable-building-materials-sustainable-in-measurable-terms","What makes sustainable building materials sustainable in measurable terms?",[16,17,18],"p",{},"Sustainable building materials are, in measurable terms, products whose declared environmental impacts are low for the job they do in the building. The measure is a set of indicators calculated by life-cycle assessment and published in an environmental product declaration (EPD). It is not a label such as \"eco friendly\" or \"green\".",[16,20,21],{},"EN 15804+A2, the European core rules for construction EPDs, defines which indicators are declared and for which life-cycle stages. The climate indicator is global warming potential (GWP), in kg CO₂e. It is declared as GWP-total, which is the sum of a fossil component, a biogenic component and a component for land use and land use change.",[16,23,24],{},"Carbon is one indicator among several. Annex II of the Construction Products Regulation, Regulation (EU) 2024\u002F3110, lists the environmental characteristics that harmonised product specifications have to cover: climate change effects, ozone depletion, acidification, three kinds of eutrophication, photochemical ozone, abiotic depletion of minerals and metals and of fossil fuels, water use, particulate matter, ionising radiation, eco-toxicity, human toxicity and land use.",[16,26,27],{},"EN 15804 sets out how these indicators are calculated and declared. It does not define a threshold below which a product counts as green. A claim about eco friendly building materials is therefore checkable only when it points to a declared figure.",[16,29,30,31,36],{},"This article concentrates on carbon, because it is the indicator that EU building rules address first (see ",[32,33,35],"a",{"href":34},"\u002Fblog\u002Fepbd-whole-life-carbon-gwp","EPBD and whole-life carbon","). The same discipline applies to the other indicators.",[11,38,40],{"id":39},"how-do-you-compare-two-products-by-carbon-footprint-fairly","How do you compare two products by carbon footprint fairly?",[16,42,43],{},"Compare two products only when their EPDs describe the same function, cover the same life-cycle modules, follow the same version of EN 15804 and are both valid. Then make the comparison for the building element, not per kilogram.",[16,45,46],{},"The standards point the same way. ISO 14025 says that declarations of this type exist to enable comparisons between products fulfilling the same function. EN 15804 defines the conditions under which construction products can be compared on the basis of their EPDs, and it expresses the data in modules so that they can be added up for a building.",[48,49,50,66],"table",{},[51,52,53],"thead",{},[54,55,56,60,63],"tr",{},[57,58,59],"th",{},"Check",[57,61,62],{},"What to look for in each EPD",[57,64,65],{},"Why it matters",[67,68,69,81,92,103,114],"tbody",{},[54,70,71,75,78],{},[72,73,74],"td",{},"Same function",[72,76,77],{},"The declared or functional unit, and the quantity each product needs",[72,79,80],{},"One kilogram of one product rarely does the work of one kilogram of another",[54,82,83,86,89],{},[72,84,85],{},"Same modules",[72,87,88],{},"Which of A1–A3, A4–A5, B, C1–C4 and D are declared",[72,90,91],{},"A product-stage figure cannot be set against a whole-life figure",[54,93,94,97,100],{},[72,95,96],{},"Same standard version",[72,98,99],{},"EN 15804+A2 or the earlier EN 15804+A1",[72,101,102],{},"The A2 amendment revised the impact indicators",[54,104,105,108,111],{},[72,106,107],{},"Valid declaration",[72,109,110],{},"The date of issue and the date until which the EPD is valid",[72,112,113],{},"An expired EPD may describe a product or process that has since changed",[54,115,116,119,122],{},[72,117,118],{},"Same kind of data",[72,120,121],{},"Product-specific, manufacturer average or sector average",[72,123,124],{},"An average hides the spread between plants and mixes",[16,126,127],{},"Three of these checks deserve a closer look.",[16,129,130,134],{},[131,132,133],"strong",{},"Function."," An EPD reports its figures for a declared unit, such as 1 kg, 1 m² or 1 m³, or for a functional unit that includes the performance delivered. A steel beam and a glued laminated timber beam designed for the same span and load do not weigh the same. The fair comparison is beam against beam, or floor against floor, with each GWP figure multiplied by the quantity that design needs.",[16,136,137,140,141,145],{},[131,138,139],{},"Modules."," Modules A1–A3 cover production. A product that looks better there can look different once transport, replacement during the life of the building and end of life are included. Module D, which reports benefits and loads beyond the system boundary, is shown separately and should stay separate. The modules are explained in ",[32,142,144],{"href":143},"\u002Fblog\u002Fgwp-building-materials-a1-a3","GWP by life-cycle module",".",[16,147,148,151,152,156],{},[131,149,150],{},"Standard version."," EN 15804+A2 superseded EN 15804+A1, and conflicting national standards had to be withdrawn by October 2022. Declarations issued under A1 may still turn up in searches and project files. Check the version stated on each document before putting two figures side by side. ",[32,153,155],{"href":154},"\u002Fblog\u002Fen-15804-en-15978-explained","EN 15804 and EN 15978 explained"," covers the differences.",[16,158,159],{},"The final comparison is made in the building itself. EN 15978 is the European method that adds product data up over the life of the building.",[11,161,163],{"id":162},"are-low-carbon-building-materials-always-the-bio-based-ones","Are low carbon building materials always the bio-based ones?",[16,165,166],{},"Not automatically. Whether a bio-based product is lower in carbon depends on which modules are read.",[16,168,169],{},"The RICS standard on whole-life carbon assessment explains the mechanism. Carbon taken up by the growing plant is counted as a removal in modules A1–A3, and the same carbon is counted as an emission in the end-of-life modules C3 and C4. Over modules A to C the biogenic carbon balances. Read on its own, an A1–A3 figure can fall simply because more biomass is used, which RICS describes as a perverse incentive.",[16,171,172],{},"Two practical consequences follow:",[174,175,176,180],"ul",{},[177,178,179],"li",{},"Read modules A to C together, or compare the fossil component of GWP, when one of the products is bio-based.",[177,181,182],{},"Keep stored carbon as separate information. How carbon storage in buildings is recognised is a matter for national rules: the recast Energy Performance of Buildings Directive requires Member States to address it (Article 7(6)).",[11,184,186],{"id":185},"why-are-top-ten-lists-of-green-building-materials-unreliable","Why are top-ten lists of green building materials unreliable?",[16,188,189],{},"They rank material categories, while a carbon footprint belongs to a specific product from a specific plant. The spread inside one category is large:",[174,191,192,198,204],{},[177,193,194,197],{},[131,195,196],{},"Steel."," The World Steel Association reports 0.69 t CO₂ per tonne of crude steel for the scrap-based electric arc furnace route and 2.34 t for the blast furnace route (2024 data, Sustainability Indicators report 2025).",[177,199,200,203],{},[131,201,202],{},"Concrete."," In the 2026 update of the UK market benchmark, the data for ready-mixed concrete of one strength class, C32\u002F40, run from 121 to 468 kg CO₂e per m³ for modules A1–A3.",[177,205,206,209],{},[131,207,208],{},"Cement."," The clinker content of cement varies from 5% to 99% by weight depending on the cement type, and clinker accounts for 94% of the emissions of cement production (Joint Research Centre, 2026).",[16,211,212,213,217],{},"A list that places \"concrete\" or \"steel\" at a fixed rank cannot reflect a spread of that size. A ranking of green building materials by category also leaves out the points that decide a comparison: the quantity needed, the modules counted, the year of the data and the document behind the figure. ",[32,214,216],{"href":215},"\u002Fblog\u002Flow-carbon-concrete-steel-epd-gwp","Low-carbon concrete and steel"," looks at those two materials in detail.",[11,219,221],{"id":220},"how-do-you-choose-eco-friendly-building-materials-in-practice","How do you choose eco friendly building materials in practice?",[16,223,224],{},"Work from the building element to the document, in this order:",[226,227,228,231,234,242,245,248],"ol",{},[177,229,230],{},"Define the element and the performance it has to deliver.",[177,232,233],{},"Shortlist real products that meet that requirement.",[177,235,236,237,241],{},"Obtain the EPD of each product. EPDs are published in the registries of programme operators, in national databases and on manufacturers' websites (see ",[32,238,240],{"href":239},"\u002Fblog\u002Fepd-database-find-valid-epd","EPD databases",").",[177,243,244],{},"Apply the five checks in the table above.",[177,246,247],{},"Multiply the GWP per module by the quantity the element needs, including replacements over the study period.",[177,249,250],{},"Record the document reference next to every figure.",[16,252,253],{},"A product without an EPD is not shown to be worse. It is simply undeclared, and a building calculation then falls back on generic data or default values, which Member States may set on conservative assumptions.",[16,255,256,257,145],{},"An assistant connected to Quarry returns, for a named product, the GWP per module as printed in the EPD, the validity dates and the document. The comparison, and the judgement about what suits the building, stay with the professional. For the wider method, see ",[32,258,260],{"href":259},"\u002Fblog\u002Fembodied-carbon-explained","embodied carbon explained",{"title":262,"searchDepth":263,"depth":263,"links":264},"",2,[265,266,267,268,269],{"id":13,"depth":263,"text":14},{"id":39,"depth":263,"text":40},{"id":162,"depth":263,"text":163},{"id":185,"depth":263,"text":186},{"id":220,"depth":263,"text":221},"Sustainable building materials are judged by declared impacts, not adjectives. How to compare two products fairly using the GWP in their EPDs.","md",[273,276,279,282,285],{"question":274,"answer":275},"What are the most sustainable building materials?","There is no universal ranking. The environmental impact of a material depends on the specific product, the plant that made it, the quantity needed to do the job and the life-cycle stages counted. The measurable route is to shortlist products that meet the technical requirement, read the global warming potential in each environmental product declaration, and compare them for the same function.",{"question":277,"answer":278},"How do I compare two building materials by carbon footprint?","Take the environmental product declaration of each product and check four things: that the quantities compared perform the same function, that the same life-cycle modules are covered, that both follow the same version of EN 15804, and that both are still valid. Then multiply each GWP figure by the quantity the building element actually needs and compare the totals.",{"question":280,"answer":281},"Are bio-based materials always lower carbon?","Not automatically. A timber or other bio-based product can show a low or negative figure for modules A1–A3, because carbon taken up during growth is counted as a removal there. The same carbon is counted as an emission in the end-of-life modules. Reading modules A to C together, or looking at the fossil part of GWP, gives a fairer picture.",{"question":283,"answer":284},"What do eco friendly and green mean for a building material?","Neither word has a threshold in the European standard for construction product declarations. EN 15804 defines how impacts are calculated and declared per life-cycle module, and it does not say which values count as green. A claim becomes checkable only when it points to a declared indicator, such as GWP in kg CO₂e per declared unit, in a valid declaration.",{"question":286,"answer":287},"Is a product without an EPD less sustainable?","Not necessarily. A missing declaration means the impact has not been declared, not that it is high. In a building calculation, generic data or default values are used instead. Under the EU framework for life-cycle GWP, Member States may set default values on conservative assumptions, so a product with its own declaration can usually be represented more precisely.",[289,290,291,292,293,294,295],"sustainable building materials","eco friendly building materials","green building materials","low carbon building materials","environmental product declaration","embodied carbon","global warming potential",{},true,"\u002Fblog\u002Fsustainable-building-materials-epd-data","2026-11-17","## What makes sustainable building materials sustainable in measurable terms?\n\nSustainable building materials are, in measurable terms, products whose declared environmental impacts are low for the job they do in the building. The measure is a set of indicators calculated by life-cycle assessment and published in an environmental product declaration (EPD). It is not a label such as \"eco friendly\" or \"green\".\n\nEN 15804+A2, the European core rules for construction EPDs, defines which indicators are declared and for which life-cycle stages. The climate indicator is global warming potential (GWP), in kg CO₂e. It is declared as GWP-total, which is the sum of a fossil component, a biogenic component and a component for land use and land use change.\n\nCarbon is one indicator among several. Annex II of the Construction Products Regulation, Regulation (EU) 2024\u002F3110, lists the environmental characteristics that harmonised product specifications have to cover: climate change effects, ozone depletion, acidification, three kinds of eutrophication, photochemical ozone, abiotic depletion of minerals and metals and of fossil fuels, water use, particulate matter, ionising radiation, eco-toxicity, human toxicity and land use.\n\nEN 15804 sets out how these indicators are calculated and declared. It does not define a threshold below which a product counts as green. A claim about eco friendly building materials is therefore checkable only when it points to a declared figure.\n\nThis article concentrates on carbon, because it is the indicator that EU building rules address first (see [EPBD and whole-life carbon](\u002Fblog\u002Fepbd-whole-life-carbon-gwp)). The same discipline applies to the other indicators.\n\n## How do you compare two products by carbon footprint fairly?\n\nCompare two products only when their EPDs describe the same function, cover the same life-cycle modules, follow the same version of EN 15804 and are both valid. Then make the comparison for the building element, not per kilogram.\n\nThe standards point the same way. ISO 14025 says that declarations of this type exist to enable comparisons between products fulfilling the same function. EN 15804 defines the conditions under which construction products can be compared on the basis of their EPDs, and it expresses the data in modules so that they can be added up for a building.\n\n| Check                 | What to look for in each EPD                                         | Why it matters                                                              |\n| --------------------- | -------------------------------------------------------------------- | --------------------------------------------------------------------------- |\n| Same function         | The declared or functional unit, and the quantity each product needs | One kilogram of one product rarely does the work of one kilogram of another |\n| Same modules          | Which of A1–A3, A4–A5, B, C1–C4 and D are declared                   | A product-stage figure cannot be set against a whole-life figure            |\n| Same standard version | EN 15804+A2 or the earlier EN 15804+A1                               | The A2 amendment revised the impact indicators                              |\n| Valid declaration     | The date of issue and the date until which the EPD is valid          | An expired EPD may describe a product or process that has since changed     |\n| Same kind of data     | Product-specific, manufacturer average or sector average             | An average hides the spread between plants and mixes                        |\n\nThree of these checks deserve a closer look.\n\n**Function.** An EPD reports its figures for a declared unit, such as 1 kg, 1 m² or 1 m³, or for a functional unit that includes the performance delivered. A steel beam and a glued laminated timber beam designed for the same span and load do not weigh the same. The fair comparison is beam against beam, or floor against floor, with each GWP figure multiplied by the quantity that design needs.\n\n**Modules.** Modules A1–A3 cover production. A product that looks better there can look different once transport, replacement during the life of the building and end of life are included. Module D, which reports benefits and loads beyond the system boundary, is shown separately and should stay separate. The modules are explained in [GWP by life-cycle module](\u002Fblog\u002Fgwp-building-materials-a1-a3).\n\n**Standard version.** EN 15804+A2 superseded EN 15804+A1, and conflicting national standards had to be withdrawn by October 2022. Declarations issued under A1 may still turn up in searches and project files. Check the version stated on each document before putting two figures side by side. [EN 15804 and EN 15978 explained](\u002Fblog\u002Fen-15804-en-15978-explained) covers the differences.\n\nThe final comparison is made in the building itself. EN 15978 is the European method that adds product data up over the life of the building.\n\n## Are low carbon building materials always the bio-based ones?\n\nNot automatically. Whether a bio-based product is lower in carbon depends on which modules are read.\n\nThe RICS standard on whole-life carbon assessment explains the mechanism. Carbon taken up by the growing plant is counted as a removal in modules A1–A3, and the same carbon is counted as an emission in the end-of-life modules C3 and C4. Over modules A to C the biogenic carbon balances. Read on its own, an A1–A3 figure can fall simply because more biomass is used, which RICS describes as a perverse incentive.\n\nTwo practical consequences follow:\n\n- Read modules A to C together, or compare the fossil component of GWP, when one of the products is bio-based.\n- Keep stored carbon as separate information. How carbon storage in buildings is recognised is a matter for national rules: the recast Energy Performance of Buildings Directive requires Member States to address it (Article 7(6)).\n\n## Why are top-ten lists of green building materials unreliable?\n\nThey rank material categories, while a carbon footprint belongs to a specific product from a specific plant. The spread inside one category is large:\n\n- **Steel.** The World Steel Association reports 0.69 t CO₂ per tonne of crude steel for the scrap-based electric arc furnace route and 2.34 t for the blast furnace route (2024 data, Sustainability Indicators report 2025).\n- **Concrete.** In the 2026 update of the UK market benchmark, the data for ready-mixed concrete of one strength class, C32\u002F40, run from 121 to 468 kg CO₂e per m³ for modules A1–A3.\n- **Cement.** The clinker content of cement varies from 5% to 99% by weight depending on the cement type, and clinker accounts for 94% of the emissions of cement production (Joint Research Centre, 2026).\n\nA list that places \"concrete\" or \"steel\" at a fixed rank cannot reflect a spread of that size. A ranking of green building materials by category also leaves out the points that decide a comparison: the quantity needed, the modules counted, the year of the data and the document behind the figure. [Low-carbon concrete and steel](\u002Fblog\u002Flow-carbon-concrete-steel-epd-gwp) looks at those two materials in detail.\n\n## How do you choose eco friendly building materials in practice?\n\nWork from the building element to the document, in this order:\n\n1. Define the element and the performance it has to deliver.\n2. Shortlist real products that meet that requirement.\n3. Obtain the EPD of each product. EPDs are published in the registries of programme operators, in national databases and on manufacturers' websites (see [EPD databases](\u002Fblog\u002Fepd-database-find-valid-epd)).\n4. Apply the five checks in the table above.\n5. Multiply the GWP per module by the quantity the element needs, including replacements over the study period.\n6. Record the document reference next to every figure.\n\nA product without an EPD is not shown to be worse. It is simply undeclared, and a building calculation then falls back on generic data or default values, which Member States may set on conservative assumptions.\n\nAn assistant connected to Quarry returns, for a named product, the GWP per module as printed in the EPD, the validity dates and the document. The comparison, and the judgement about what suits the building, stay with the professional. For the wider method, see [embodied carbon explained](\u002Fblog\u002Fembodied-carbon-explained).",6,{"title":5,"description":270},{"loc":298,"lastmod":299},[305,309,313,317,320,323,327,331,335,339],{"title":306,"publisher":307,"url":308},"EN 15804:2012+A2:2019 Sustainability of construction works - Environmental product declarations - Core rules for the product category of construction products (official preview: contents, foreword, introduction and scope)","Slovak Office of Standards, Metrology and Testing (ÚNMS SR)","https:\u002F\u002Fnormy.normoff.gov.sk\u002Fnorma\u002F130702\u002Fnahlad",{"title":310,"publisher":311,"url":312},"EVS-EN ISO 14025:2010 Environmental labels and declarations - Type III environmental declarations - Principles and procedures (ISO 14025:2006)","Estonian Centre for Standardisation and Accreditation (EVS)","https:\u002F\u002Fwww.evs.ee\u002Fen\u002Fevs-en-iso-14025-2010",{"title":314,"publisher":315,"url":316},"Regulation (EU) 2024\u002F3110 of the European Parliament and of the Council of 27 November 2024 laying down harmonised rules for the marketing of construction products, Annex II","Official Journal of the European Union, EUR-Lex","https:\u002F\u002Feur-lex.europa.eu\u002Feli\u002Freg\u002F2024\u002F3110\u002Foj",{"title":318,"publisher":315,"url":319},"Commission Delegated Regulation (EU) 2026\u002F52 of 16 December 2025 amending Annex III to Directive (EU) 2024\u002F1275 as regards the Union framework for the national calculation of life-cycle global warming potential","https:\u002F\u002Feur-lex.europa.eu\u002Feli\u002Freg_del\u002F2026\u002F52\u002Foj",{"title":321,"publisher":315,"url":322},"Directive (EU) 2024\u002F1275 of the European Parliament and of the Council of 24 April 2024 on the energy performance of buildings (recast)","https:\u002F\u002Feur-lex.europa.eu\u002Feli\u002Fdir\u002F2024\u002F1275\u002Foj",{"title":324,"publisher":325,"url":326},"Whole life carbon assessment for the built environment, RICS professional standard, 2nd edition (version 3, August 2024)","Royal Institution of Chartered Surveyors","https:\u002F\u002Fwww.rics.org\u002Fcontent\u002Fdam\u002Fricsglobal\u002Fdocuments\u002Fstandards\u002FWhole_life_carbon_assessment_PS_Sept23.pdf",{"title":328,"publisher":329,"url":330},"EN 15978:2026 - A Harmonized Method to Assess the Environmental Performance of Buildings","CEN-CENELEC","https:\u002F\u002Fwww.cencenelec.eu\u002Fnews-events\u002Fnews\u002F2026\u002Fen-in-the-spotlight\u002F2026-04-17-en-15978-2026\u002F",{"title":332,"publisher":333,"url":334},"Sustainability Indicators report 2025","World Steel Association","https:\u002F\u002Fworldsteel.org\u002Fwider-sustainability\u002Fsustainability-indicators\u002F",{"title":336,"publisher":337,"url":338},"LCCG Market Benchmark for the embodied carbon of concrete, 2026 update (spreadsheet version 5.0)","MPA The Concrete Centre on behalf of the Low Carbon Concrete Group","https:\u002F\u002Fwww.concretecentre.com\u002Fmarketbenchmark",{"title":340,"publisher":341,"url":342},"Mapping the transition of the EU cement industry to carbon neutrality, Science for Policy Brief JRC144123 (2026)","European Commission, Joint Research Centre","https:\u002F\u002Fpublications.jrc.ec.europa.eu\u002Frepository\u002Fbitstream\u002FJRC144123\u002FCement_factsheet_JRC144123.pdf","blog\u002Fsustainable-building-materials-epd-data","A building material is sustainable in measurable terms when its declared environmental impacts, above all its global warming potential (GWP) per life-cycle module, are low for the function it performs in the building. Two products can be compared fairly only when their EPDs describe the same function, cover the same modules, follow the same version of EN 15804 and are still valid. Generic lists of green materials cannot show this, because the footprint of one material varies several-fold from product to product.",[346,347,348,349,350],"The measure of a sustainable material is a set of declared indicators in an EPD, led by GWP in kg CO₂e, not a label.","Compare only on the same function, the same life-cycle modules, the same version of EN 15804 and valid declarations.","For bio-based products, biogenic carbon removed in A1–A3 is balanced by emissions at end of life, so read modules A to C together.","In 2024 steelmaking ranged from 0.69 to 2.34 t CO₂ per tonne of crude steel depending on the route, so a ranking by material category says little.","The comparison belongs at the level of the building element or the building, as in EN 15978.",1252,"IwIvxIOrpOaDXnlKOwEG41oXR3DM3JhpyyGPBLbixaw",[354,360,363],{"path":355,"title":356,"description":357,"publishedAt":299,"updatedAt":299,"primaryKeyword":358,"readingMinutes":359},"\u002Fblog\u002Fai-for-architects-material-data","AI for architects: asking about materials and getting a cited source","How AI for architects handles material questions: why a connected assistant can cite the EPD behind a carbon figure, and what you still check yourself.","ai for architects",7,{"path":259,"title":361,"description":362,"publishedAt":299,"updatedAt":299,"primaryKeyword":294,"readingMinutes":301},"Embodied carbon explained: what it is and how it is calculated","Embodied carbon is the greenhouse gas emitted to make, install, maintain and dispose of building materials. How it is defined, calculated and sourced.",{"path":154,"title":364,"description":365,"publishedAt":299,"updatedAt":299,"primaryKeyword":366,"readingMinutes":359},"EN 15804+A2 and EN 15978 explained for people who use EPDs","What EN 15804 requires of an EPD, what changed from +A1 to +A2, why the two are not comparable, and how EN 15978 uses EPD data in a building LCA.","en 15804",1795523510664]